PCR Equipment and Supplies
Risultati della ricerca filtrata
Applied Biosystems™ TaqMan™ QSY and QSY2 Probes
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Applied Biosystems TaqMan QSY and QSY2 probes are dual-labeled probes used for real-time PCR. TaqMan QSY and QSY2 Probes are designed for optimal sensitivity and performance in multiplexed qPCR experiments for detection of up to 6 targets.
| Shipping Condition | Room Temperature |
|---|---|
| Forma | Liquid or Dried Down |
| Metodo di rilevamento | Primer-probe |
| Internal Probe Modification | None |
| Metodo di purificazione | HPLC |
| Linea di prodotti | TaqMan |
| Green Features | Sustainable packaging |
| PCR Method | qPCR |
| Formato | Tube |
Applied Biosystems™ TaqMan™ MGB Probe
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Custom TaqMan probes are dual-labeled primers suitable for use in any real-time PCR application. They incorporate a 5' reporter dye and a 3' nonfluorescent quencher/minor groove binder (MGB). Choose among FAM, VIC, ABY, JUN, Cy5, TET, and NED as reporters.
| Da utilizzare con (apparecchiatura) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
|---|---|
| Purity or Quality Grade | HPLC |
| Forma | Liquid |
| Internal Probe Modification | None |
| Da utilizzare con (applicazione) | Real Time PCR (qPCR) |
| Metodo di purificazione | HPLC |
| Linea di prodotti | TaqMan |
| Green Features | Sustainable packaging |
| 3'Primer Modification | MGB-NFQ |
| Formato | Tube |
Applied Biosystems™ Sequence Detection Primer
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Sequence Detection Primer
| Shipping Condition | Room Temperature |
|---|---|
| Da utilizzare con (apparecchiatura) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex, QuantStudio™ Absolute Q Digital PCR System |
| Content And Storage | 1 tube containing an unlabeled primer in solution or dried down. Store at -15°C to -25°C |
| Forma | Liquid or Dried Down |
| Product Type | Sequencing Primer |
| Da utilizzare con (applicazione) | Real Time PCR Applications |
| Primer | Unlabeled |
| Metodo di purificazione | Desalted |
| Product Line | Applied Biosystems |
Eppendorf™ Mastercycler™ X40
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Mastercycler X40 combines properties that raise your standard in end-point PCR. Classic features such as a 12-column gradient and ideal block temperature homogeneity are enhanced by an easy, intuitive user interface, a touchscreen and a protective SafeLid to protect your samples from evaporation.
| Warranty | 2 Years |
|---|---|
| Velocità di riscaldamento max (blocco termico) | 3.3 °C/sec. |
| Dimensions | 24.5 x 38.5 x 23 cm (9.7 x 15.2 x 9.1 in.) |
| Uniformità termica | 20°C to 72°C ≤±0.2°C, 72°C to 95°C ≤±0.3°C |
| Velocità di raffreddamento max | 1.5°C/sec. |
| Block Format | Fixed |
| Interfaccia utente | Touchscreen |
| Capacità | 0.1 to 0.2 mL/Well |
| Intervallo gradienti | 1°C to 30°C |
| N. di programmi | 5000 |
| Configurazioni blocchi | 96-well |
| Peso | 7.25 kg |
| Precisione termica | ±0.15°C |
| Materiale | Aluminum |
| Product Type | Thermal Cycler |
| Intervallo termico | 4°C to 99°C |
| Coperchio riscaldato | 37°C to 110°C |
Applied Biosystems™ TaqMan™ TAMRA Probe
Greener Choice Product
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
This product offers one or more environmental benefits itemized in the U.S. FTC Green Guides.
Learn More About the Greener Choice Program
Custom TaqMan™ Probe
| Shipping Condition | Room Temperature |
|---|---|
| Content And Storage | 1 tube containing a dual-labeled probe in solution or dried down. Store at -15°C to -25°C |
| Purity or Quality Grade | HPLC |
| Internal Probe Modification | None |
| Linea di prodotti | TaqMan |
| Green Features | Sustainable packaging |
| Formato | Tube |
| Da utilizzare con (apparecchiatura) | 7500 System, 7500 Fast System, 7900HT System, StepOne™, StepOnePlus™, ViiA™ 7 System, QuantStudio™ 3, QuantStudio™ 5, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, QuantStudio 6 Pro, QuantStudio 7 Pro, QuantStudio™ 12k Flex |
| Forma | Liquid or Dried Down |
| Product Type | TAMRA Probe |
| 5'Primer Modification | FAM, TET, VIC |
| Da utilizzare con (applicazione) | Real Time PCR (qPCR) |
| Metodo di purificazione | HPLC |
| 3'Primer Modification | TAMRA |