missing translation for 'onlineSavingsMsg'
Learn More

Merck Filtri in fibra di vetro senza leganti

Codice prodotto. 10004570 Sfoglia Tutto Merck Prodotti
Cambia vista
Click to view available options
Diametro (sistema metrico):
1 cm
2.4 cm
2.5 cm
3.7 cm
4.7 cm
7 cm
9 cm
124 mm
14.2 cm
20.3 cm
Grado:
AP40
APFF
Quantità:
100 Pk.
50 Pk.
500 Pk.
Dimensione della confezione:
pezzi 100
pezzi 50
pezzi 500
15 product options available for selection
Product selection table with 15 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Diametro (sistema metrico) Grado Quantità unitSize
10004570 4.7 cm AP40 500 Pk. pezzi 500
10635591 3.7 cm AP40 500 Pk. pezzi 500
10598442 2.4 cm AP40 500 Pk. pezzi 500
10379980 14.2 cm AP40 50 Pk. pezzi 50
10498603 2.5 cm AP40 100 Pk. pezzi 100
10572844 4.7 cm AP40 100 Pk. pezzi 100
10588442 1 cm AP40 100 Pk. pezzi 100
10437221 14.2 cm APFF 50 Pk. pezzi 50
10697121 2.5 cm APFF 100 Pk. pezzi 100
11758792 124 mm APFF 50 Pk. pezzi 50
10480021 9 cm APFF 50 Pk. pezzi 50
10340131 9 cm AP40 100 Pk. pezzi 100
10498793 7 cm AP40 100 Pk. pezzi 100
10257770 4.7 cm APFF 100 Pk. pezzi 100
11768772 20.3 cm AP40 50 Pk. pezzi 50
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 15 options available.
15 options
Codice prodotto. 10004570 Fornitore Merck N. del fornitore AP4004705
Solo null disponibili
Aggiungi al carrello
Edge
Aggiungi al carrello

Choose from six grades of filters. Glass Fiber Filters without Binders are made of borosilicate microfiber glass. Available in multiple pore sizes and flow rates for a variety of filtration and analysis applications utilizing depth filters. Autoclavable.

For prefiltration and contamination analysis

OverviewMillipore fibrous disc filters are available in a wide range of flow rates and throughput capacities. Our Glass Fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar).Glass Fiber Filters with Binder Resin:Millipore filters with binder resin have superior wet strength and are excellent for qualitative analysis and prefiltration, especially for heavily contaminated liquids. They are also widely used for clarification of aqueous solutions.

Type AP15

  • Lowest dirt-holding capacity
  • Recommended prefilter for 0.2 to 0.6 μm filters

Type AP20

  • Lower retention, higher dirt-holding capacity than AP15 filters
  • Recommended prefilter for 0.8 to 8.0 μm filters
  • Use upstream to protect type AP15 filters

Type AP25

  • Added thickness yields same retention and greater dirt-holding capacity as AP20
  • Recommended prefilter for 0.9 to 8 μm filters, especially for proteinaceous and heavily contaminated liquids
  • Use upstream to protect type AP15 filters Glass Fiber Filters without Binder Resin:The filters without binder resin retain their structural integrity without weight loss when heated up to 500°C and can therefore be used in gravimetric analysis as well as for the filtration of hot gases.

Type APFA

  • Retains fine particles with good efficiency, even at high flow rates
  • Recommended for monitoring wastewater and collecting suspended particles in gases (e.g., fumes from chimneys)
  • Use in biochemical applications (e.g., collection of cells and filtration of protein or nucleic acid precipitates)

Type APFB

  • Higher mechanical strength when wet and greater loading capacity than type APFA filters
  • Use for liquid clarification, quantification of solids in suspensions of fine particles, and scintillation counting

Type APFC

  • Greater retention, especially for fine particulate and microorganism removal than type APFA filters
  • Use for determining total suspended solids in drinking water
  • Use for filtering proteins or nucleic acid TCA precipitates and for collecting cells and microorganisms

Type APFD

  • Thick filter with high flow and low retention
  • Use for clarifying suspensions containing particulates greater than 1.0 μm

Type APFF

  • Use for filtering extremely fine precipitates such as protein, nucleic acids, or serum precipitates
  • Recommended for USEPA method 1311 for TCLP analysis

Type AP40

  • Recommended for Standard Methods Total Suspended Solids 2540D
  • Recommended for USEPA method 1311 for TCLP analysis
  • Maintains structural integrity without weight loss when ignited to 550°C (1022°F) after sample filtration
  • Recommended for determining volatile suspended matter in wastewater and industrial effluents
TRUSTED_SUSTAINABILITY

Specifica

Velocità di flusso dell'aria 44.5 L/min/ cm2
Resistenza dell'aria 50 mm di H2O
Autoclavabile
Colore Bianco
Tipo di filtro Filtro spesso
Materiale Vetro in microfibra borosilicato
Particle Retention 0.7μ m
Dimensione del poro 0.7μ m
Sterilità Sterile
Portata 6 mL/min/ cm2
Da utilizzare con (applicazione) Determinazione delle sostanze volatili sospese nelle acque reflue e negli effluenti industriali
Grado AP40
Idrofobicità Hydrophilic
Quantità 500 Pk.
Tipo di superficie Liscio
Temperatura (sistema imperiale) max 1022°F
Temperatura (sistema metrico) max 550 °C
Spessore (sistema imperiale) 0.018 in.
Spessore (sistema metrico) 475μ m
Tipo Filter Membranes
Bagnabilità Idrofilo
Diametro (sistema imperiale) 1.8 in.
Diametro (sistema metrico) 4.7 cm
Diametro (sistema metrico) disco 4.7 cm
Vedi altri risultati Mostra meno risultati
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.