Description
- Ready-to-use columns for convenient process development
- Rigid, highly cross-linked agarose matrix
- Bed height of 10cm is designed to allow method optimization and parameter screening
- Easily connected in series to achieve 20cm bed height
- Small bed volume (4.7mL) gives fast result and minimal sample/buffer consumption
- Reproducible results, scalable to BioProcess columns packed with the same chromatography media using the same linear fluid velocity
MabSelect
- For capture of MAbs from large sample volumes
- Prepacked with protein A-derived media
- Compatible with high flow rates and high pressure when scaling up
- Increased binding capacity enables purification of MAbs from high-level expression feedstock
- Also optimized for Fc-fusion proteins
- Very low, unspecific binding due to high ligand selectivity and matrix hydrophilicity
- Prepacked with protein A-derived media
- With novel, alkali-tolerant recombinant protein A ligand that provides greater stability and allows use of 0.1 to 0.5M sodium hydroxide for cleaning-in-place (CIP)
- Enhanced protease resistance resulting in lower ligand leakage
- High dynamic binding capacity
Specifications
Specifications
| Tampone | 8M Urea, 6M Guanidine Hydrochloride, 2% Benzyl Alcohol or 20% Ethanol |
| Tipo di colonna | HiScreen MabSelect Prepacked Column |
| Descrizione | Bed Dimensions: 7.7 × 100 mm |
| Include | Stoppers at the inlet and outlet |
| Dimensioni kit | 1 x 4.7mL |
| Supporto del letto | Filter |
| Diametro (sistema imperiale) interno | 0.3 in. |
| Capacità di legame | ≈30mg Human IgG |
| Diametro (sistema metrico) interno | 0.77cm |
| Product Type | HiScreen MabSelect Prepacked Column |
| Show More |
Safety and Handling
Product Identifier
- HiScreen MabSelect
- Attenzione
- Liquido infiammabile Categoria 3
- H226-Liquido e vapori infiammabili.
- P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contain: ethanol