Learn More
Thermo Scientific™ LightShift™ Chemiluminescent RNA EMSA Kit
Sfoglia Tutto Thermo Scientific ProdottiDescrizione
Thermo Scientific™ LightShift Chemiluminescent RNA EMSA Kit provides a non-radioactive solution for studying RNA-protein interactions using an electrophoretic mobility-shift assay (EMSA).
Highlights:
Sensitive – chemiluminescent detection comparable to radioactive detection
Time-saving – develop X-ray films after 1- to 5-minute exposures, versus 16 hour exposures needed with radioactive systems
Flexible – compatible with RNA probes biotinylated by different methods
Easy to use – complete kit includes optimized reagents for binding reactions and RNA probe detection
Non-radioactive – eliminate waste concerns from radioactive RNA probes
Specifica
Specifica
| Saggio | EMSA Assay |
| Content And Storage | Sufficient For: 100 binding reactions and detection on 1000 cm2 of membrane (10 mini-gel blots)• 125 nM Biotinylated IRE RNA Control 35 μL (store at -20°C) • 10 μM Unlabeled IRE RNA Control, 25 μL (store at -20°C) • 2 mg/mL Cytosolic Liver Extract, 50 μL (store at -20°C) • 10 mg/mL tRNA, 100 μL (store at -20°C) • 10X REMSA Binding Buffer, 1 mL (store at -20°C) • 50% Glycerol, 500 μL (store at -20°C) • 2M KCl, 500 μL (store at -20°C) • 1M MgCl2, 500 μL (store at -20°C) • DTT, lyophilized (store at -20°C) • Nuclease-Free Water, 1.5 mL (store at -20°C) • 5X REMSA Loading Buffer, 1 mL (store at -20°C) • Stabilized Streptavidin-HRP, 1.5 mL (store at 4°C) • Luminol/Enhancer Solution, 80 mL (store at 4°C) • Stable Peroxide Solution, 80 mL (store at 4°C) • Nucleic Acid Detection Blocking Buffer, 500 mL (store at 4°C) • 4X Wash Buffer, 500 mL (store at 4°C) • Substrate Equilibration Buffer, 500 mL (store at 4°C) |
| Metodo di rilevamento | Chemiluminescence |
| Formato | Kit |
| Tipo di campione | Protein |
| Da utilizzare con (apparecchiatura) | myECL™ Imager, X-Ray Film |
| N. di reazioni | 100 reactions |
| Linea di prodotti | LightShift |
| Product Type | LightShift Chemiluminescent RNA EMSA Kit |
| Quantità | 100 reactions |
| Vedi altri risultati |
For Research Use Only. Not for use in diagnostic procedures.
Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.