METTLER TOLEDO™ Ion Selective Electrodes (ISE)

Codice prodotto. 11917821 Sfoglia Tutto Mettler Toledo Prodotti
Cambia vista
Click to view available options
Tipi di connettore:
BNC
S7 BNC Cable
Modello:
perfectION Ag+/S2- Combination Electrode
perfectION CI- Combination Electrode
perfectION CN- Combination Electrode
perfectION CU2+ Combination Electrode
perfectION Ca+2 Combination Electrode
perfectION DX223-Na+ Half-Cell Electrode
perfectION DX235-Cl- Half-Cell Electrode
perfectION FI- Combination Electrode
perfectION I- Combination Electrode
perfectION K+ Combination Electrode
perfectION NO3- Combination Electrode
perfectION Na+ Combination Electrode
perfectION Pb2+ Combination Electrode
Intervallo di misurazione:
0.002 to 23000 mg/L
0.005 to 127000 mg/L
0.02 mg/ - saturated solution
0.02 to 40100 mg/L
0.04 to 39000 mg/L
0.1 to 14000 mg/L
0.2 to 20700 mg/L
0.2 to 260 mg/L
1.0 to 1 x 10-7 mol/L
1.0 to 1.0-5 mol/L
1.8 to 35500 mg/L
6.4 x 10-6354 mg/L
Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L
Dimensione della confezione:
Pezzo
13 product options available for selection
Product selection table with 13 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Tipi di connettore Modello Intervallo di misurazione unitSize
11917821 S7 BNC Cable perfectION Na+ Combination Electrode 0.002 to 23000 mg/L Pezzo
11987811 BNC perfectION CI- Combination Electrode 1.8 to 35500 mg/L Pezzo
11977811 BNC perfectION Ca+2 Combination Electrode 0.02 to 40100 mg/L Pezzo
11997811 BNC perfectION CN- Combination Electrode 0.2 to 260 mg/L Pezzo
11907821 BNC perfectION CU2+ Combination Electrode 6.4 x 10-6354 mg/L Pezzo
11967811 BNC perfectION Ag+/S2- Combination Electrode Ag+: 0.01 to 108000 mg/L; S2-: 0.003 to 32000 mg/L Pezzo
10566415 BNC perfectION FI- Combination Electrode 0.02 mg/ - saturated solution Pezzo
11927821 BNC perfectION I- Combination Electrode 0.005 to 127000 mg/L Pezzo
11947821 BNC perfectION NO3- Combination Electrode 0.1 to 14000 mg/L Pezzo
11937821 BNC perfectION K+ Combination Electrode 0.04 to 39000 mg/L Pezzo
10145642 S7 BNC Cable perfectION DX223-Na+ Half-Cell Electrode 1.0 to 1 x 10-7 mol/L Pezzo
10067810 S7 BNC Cable perfectION DX235-Cl- Half-Cell Electrode 1.0 to 1.0-5 mol/L Pezzo
11957821 BNC perfectION Pb2+ Combination Electrode 0.2 to 20700 mg/L Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 13 options available.
13 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 11917821 Fornitore METTLER TOLEDO™ N. del fornitore 51344724
Solo null disponibili
Aggiungi al carrello
Aggiungi al carrello
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

A selection of ISE probes for detecting concentration of various free ions.

  • Prior to first use, rinse the electrode with distilled water and soak it in the appropriate standard for 24-48 hours and then fill with reference electrolyte (refer to table above)
  • ISA (Ionic strength adjuster) solution required to be added to all calibration standards and samples prior to measurement for accurate results
  • Refer to electrode user manual for appropriate ratio of ISA solution to sample volume
  • Add filling solution each day before using the electrode (at least 2.5 cm above sample level in beaker)
  • Be sure to screw cap tightly immediately after use
  • The filling solution inside the electrode should not be allowed to evaporate, as crystallization will result
  • For storage between measurements and up to three days, store in the appropriate standard
  • For long-term storage, refer to specific ISE electrode user manual
  • Sensing membrane will wear over time; each membrane can last about six months with normal use, but actual lifespan will depend on the type of samples that are being measured
  • Competing ion interferences are common. Refer to ISE electrode user manual for potential interferences
  • Compatible with METTLER TOLEDO SevenExcellence Benchtop, Seven2Go, and SevenGo Portable
  • Compatible with InMotion Autosampler to automate measurement and cleaning of up to 303 samples
TRUSTED_SUSTAINABILITY

Specifica

Applicazioni For determination of Sodium ions
Tipi di connettore S7 BNC Cable
Descrizione Required Solutions: Reference Electrolyte - 3 mol/L KCl - 51350072 Ionic Strength Adjuster - NH4Cl / NH4OH
Tipo di soluzione di riempimento 3 mol/L KCl
Lunghezza (sistema imperiale) 4.75 in.
Lunghezza (sistema metrico) 120 mm
Materiale Epoxy
Temperatura (sistema imperiale) operativa 32° to 176°F
Intervallo di pH 8 to 11
Interferenze 3mol/L KCl
Membrana Na+ Glass
Modello perfectION Na+ Combination Electrode
Temperatura (sistema metrico) operativa 0°C to 80°C
Tipo Ion Selective Electrode
Intervallo di misurazione 0.002 to 23000 mg/L
Parametro Sodium
Vedi altri risultati Mostra meno risultati
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.