missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Pierce™ Gaussia Luciferase Flash Assay Kit

Codice prodotto. 12132240 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Quantità:
100 Reaction Kit
1000 Reaction Kit
Dimensione della confezione:
Pezzo
2 product options available for selection
Product selection table with 2 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantità Dimensione della confezione
12132240 1000 Reaction Kit Pezzo
12122240 100 Reaction Kit Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 2 options available.
2 options
Les retours ne sont pas autorisés pour ce produit. View return policy
Product Code. 12132240 Supplier Thermo Scientific™ Supplier No. 16159
 Articolo soggetto a restrizioni
Spedizione stimata: 23-11-2026
Add to basket
Add to basket

missing translation for 'validMainframeMsg'

This item is not returnable. View return policy

Assay regulatory element transcriptional activity in mammalian culture media or whole cell lysates with this highly sensitive flash-based Gaussia luciferase kit.

The Thermo Scientific Pierce Gaussia Luciferase Flash Assay Kit provides researchers with the most sensitive assay for transcriptional activity of regulatory elements in mammalian cell culture media and whole cell lysate.

Features of the Gaussia Luciferase Flash Assay Kit:

  • Sensitive—1000 times greater sensitivity allows utilization of smaller numbers of cells
  • Cost effective—highest sensitivity assays result in decreased reagent consumption
  • Secreted luciferase—allows real-time assays and kinetic studies without destroying cells
  • Time-saving—assays using secreted luciferases require minimal sample handling
  • Automation-friendly—amenable to high throughput screens
  • Convenient—contains a universal cell lysis buffer and optimized flash assay reagent
  • Safe—allows one to perform non-radioactive assays

This Flash Assay Kit contains reagents for measuring the activity of Gaussia luciferase in mammalian cell culture media and lysates. When used with Thermo Scientific Gaussia Luc Vectors, the kit provides an extremely sensitive bioluminescent reporter assay system for secreted or intracellular detection of promoter or pathway activity. Gaussia luciferase is highly secreted into the cell culture media, allowing for live cell monitoring of reporter activity. The signal produced by Gaussia is considerably greater than signal from either firefly or Renilla luciferases assayed under similar conditions.

Includes:

Cell lysis buffer, reaction buffer and substrate

Requires:

Gaussia luciferase and luminometer or other instrument capable of monitoring luminescence, such as the Varioskan ALF or the Varioskan LUX microplate readers.

Applications:

  • Promoter studies for analyzing cis- regulatory elements and trans-acting factors
  • Drug screening
  • siRNA and miRNA screening
  • Multiplexed assays to study off-target effects
  • Secretory pathway/protein localization reporter assays
  • Signal transduction pathway analysis
  • RNA splicing studies

Gaussia luciferase is a 20kDa protein from the marine copepod, Gaussia princeps. The bioluminescent enzyme is highly secreted into the cell culture media, allowing for live cell monitoring of reporter activity. Light output generated by the luciferase reaction can be correlated to the amount of Gaussia luciferase protein produced and used to determine the activity of the promoter driving Gaussia expression. The signal produced by Gaussia luciferase shows strong flash kinetics and is considerably greater than flash signals from either firefly or Renilla luciferases assayed under similar conditions. The assay kit is optimized for use with our Gaussia Luc Vectors but is fully compatible with other Gaussia luciferases and derivatives that use coelenterazine as a substrate. (For glow assays, use our Gaussia-Dura Luc Vectors.)

TRUSTED_SUSTAINABILITY

Specifications

Tipo Assay Kit
Bersaglio Luciferase, Gaussia Luciferase
Sufficiente per 1000 Luciferase Assays
Quantità 1000 Reaction Kit
Content And Storage Sufficient For: 1000 luciferase assays in microplate wells
• Gaussia Flash Assay Buffer, 50 mL (store at 4°C)
• 100X Coelenterazine, 0.5 mL (store at -80°C)
• Luciferase Cell Lysis Buffer (2X), 60 mL (store at room temperature)

Kit may be stored at -80°C, or individually at indicated temperatures.
Saggio Reporter Enzyme, Luciferase Reporter Assay
Compatible Cells Mammalian Cells
Metodo di rilevamento Bioluminescence
Da utilizzare con (apparecchiatura) Luminometer
Formato 96-well Plate, 384-well Plate
Tipo di etichetta Enzyme Labeled
Substrate Properties Chemical Substrate
Tecnica Enhanced Chemiluminescence
Tipo di substrato Luciferase Substrate
Linea di prodotti Pierce
Substrato Coelenterazine
Show More Show Less
compliance-icons compliance-icons compliance-icons
Product Identifier
  • Pierce Gaussia Luciferase Flash Assay Kit
Signal Word
  • Pericolo
Hazard Category
  • Tossicità acuta Categoria 3
  • Liquido infiammabile Categoria 2
  • Tossicità specifica per organi bersaglio (esposizione singola) Categoria 1
Hazard Statement
  • H225-Liquido e vapori facilmente infiammabili.
  • H301-Tossico se ingerito.
  • H311-Tossico per contatto con la pelle.
  • H331-Tossico se inalato.
  • H370-Provoca danni agli organi.
Precautionary Statement
  • P210-Tenere lontano da fonti di calore, superfici riscaldate, scintille, fiamme e altre fonti di innesco. Vietato fumare.
  • P241-Utilizzare impianti elettrici/di ventilazione/d'illuminazione/ a prova di esplosione.
  • P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P301+P310-IN CASO DI INGESTIONE: contattare immediatamente un CENTRO ANTIVELENI/un medico
  • P303+P361+P353-IN CASO DI CONTATTO CON LA PELLE (o con i capelli): togliere immediatamente tutti gli indumenti contaminati. Sciacquare la pelle/fare una doccia.
  • P304+P340-IN CASO DI INALAZIONE: trasportare l'infortunato all'aria aperta e mantenerlo a riposo in posizione che favorisca la respirazione.
  • P403+P235-Conservare in luogo fresco e ben ventilato.
  • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Supplemental information
  • MIXTURE LIST-Contain: Methanol

For Research Use Only. Not for use in diagnostic procedures.

Product Title
Select an issue

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.