Thermo Scientific™ Kit di quantificazione cromogenica LAL di endotossine Pierce™

Codice prodotto. 12117850 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Quantità:
50 Tests
Dimensione della confezione:
1 set
1 product options available for selection
Product selection table with 1 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Quantità unitSize
12117850 50 Tests 1 set
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 1 options available.
1 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 12117850 Fornitore Thermo Scientific™ N. del fornitore 88282

This item is currently unavailable or has been discontinued.
View the product page for possible alternatives.
Visualizzare prodotti alternativi

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Accurately measure endotoxin levels (LPS, lipopolysaccharides) in protein, peptide or antibody samples using our Limulus Amebocyte Lysate (LAL) assay.

The Thermo Scientific™ Pierce LAL Chromogenic Endotoxin Quantitation Kit measures the amount of endotoxin in a protein, peptide or antibody sample using the Limulus Amebocyte Lysate (LAL) assay.

The endotoxin concentration in a sample is measured using the Pierce LAL Chromogenic Endotoxin Quantitation Kit via a chromogenic signal generated in the presence of endotoxins. Samples can be measured on a microplate absorbance reader at 405nm. A standard curve is created using the E. coli endotoxin standard included with each kit to calculate endotoxin levels as low as 0.1 EU/mL. Protein and antibody samples can be assayed in as little as 30 minutes. Determining endotoxin levels is important to assess the efficiency of endotoxin removal methods and prevent endotoxic shock, inflammation and/or sepsis in tissue culture cells and animals injected with endotoxin-contaminated proteins.

Highlights:

  • Sensitive—detect as little as 0.1 EU/mL

  • Fast—perform this assay in 30 minutes

  • Economical—assay requires only 10μL of a protein sample

  • AccurateE. coli O111:B4 standard in each kit enables accurate endotoxin quantitation

  • Versatile—405nm absorbance reading is compatible with common ELISA plate readers

Recommended for:

Quantitation of endotoxin levels in a protein, peptide or antibody solution

TRUSTED_SUSTAINABILITY

Specifica

Content And Storage Upon receipt store at 4°C. Product shipped with an ice pack.
Saggio [other]
Metodo di rilevamento Colorimetric
Da utilizzare con (apparecchiatura) Spectrophotometer, Microplate Reader
Product Line Pierce
Quantità 50 Tests
Da utilizzare con (applicazione) Solution-Based Detection, Absorbance
Bersaglio Not Target-Specific
Tipo Endotoxin Quantitation Kit
Formato Kit
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.