missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ Biglie magnetiche NHS-attivate Pierce™

Codice prodotto. 12331893 Sfoglia Tutto Thermo Scientific Prodotti
Click to view available options
Quantità:
1 ml
5 mL
Dimensione della confezione:
1mL
5mL
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Codice prodotto. 12331893

Marca: Thermo Scientific™ 88826

Effettua il per acquistare questo articolo Hai bisogno di un conto web ? Registrati oggi stesso!

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Immobilize proteins or other ligands for magnetic separation affinity purification with these magnetic particles coated with amine-reactive NHS-ester groups.

Thermo Scientific Pierce NHS-Activated Magnetic Beads enable covalent, amine-based conjugation of proteins to magnetic beads in a simple mix-and-go format for use in custom affinity purification experiments.

Features of NHS-Activated Magnetic Beads:

  • High capacity—at least four times higher binding capacity than NHS-activated magnetic beads from other suppliers
  • Easy to use—immobilize in a simple one-step reaction with minimal hands-on time
  • Safe—no hazardous chemicals needed (e.g., sodium cyanoborohydride and cyanogen bromide)
  • Ligand-compatible—use to immobilize with nearly any primary amine-containing compound or affinity ligand
  • Low non-specific binding—the bead surface is pre-blocked and any nonreacted NHS-ester groups are fully quenched
  • Protocol-compatible—protein coupling to the beads and downstream applications can be performed manually or by automation (e.g., Thermo Scientific KingFisher Instruments)

The activated magnetic beads contain N-hydroxy-succinimide (NHS) functional groups that react with primary amines forming stable amide linkages. Once they are covalently attached, the immobilized proteins are highly resistant to leaching from the bead surface. When prepared beads are used in experiments, nonspecific binding is negligible because nonreacted NHS-ester groups are thoroughly blocked during the coupling procedure. Pierce NHS-Activated Magnetic beads can be coupled and processed either manually with a magnetic stand or with automated platforms such as the Thermo Scientific KingFisher Instruments.

Applications:

  • Immobilization of ligands for the purification of recombinant proteins
  • Immobilization of antibodies for immunoprecipitations and co-immunoprecipitations free of antibody contamination in the eluates
  • Immobilization of secondary antibody for the affinity purification of antibody subtypes from ascites, serum and cell culture supernatant

Pierce NHS-Activated Magnetic Beads offer a convenient way to conjugate any desired protein to a magnetic bead surface. The process does not require hazardous chemicals or lengthy reaction schemes. The beads are first incubated with protein for 1 to 2 hours in an amine free buffer at pH 7 to 9 to allow for covalent coupling through NHS-ester chemistry. The beads are subsequently washed and then any remaining active NHS-ester groups are quenched. The amine reactive chemistry and subsequent quench are completed in 3 to 4 hours. Coupled protein does not leach from the bead surface. In addition, the beads exhibit very low non-specific binding due to effective quenching and a proprietary blocking agent that coats the surface of the base particle. Following conjugation the prepared magnetic beads are typically used in affinity purification procedures.

TRUSTED_SUSTAINABILITY

Specifica

Capacità (sistema metrico) 1 mL
Concentrazione Slurry: 10 mg/mL, 1% solids
Content And Storage Upon receipt store at 4°C. Product shipped with an ice pack.
Surface Functionality NHS Ester
Dimensione particelle 1 μm
Forma Liquid
Product Line Pierce
Quantità 1 ml
Protein Form Recombinant
Bersaglio Amine
Tipo Magnetic Affinity Bead
Vedi altri risultati Mostra meno risultati
compliance-icons compliance-icons
Identificativo prodotto
  • Pierce NHS-Activated Magnetic Beads
Avvertenza
  • Pericolo
Categoria di pericolo
  • Tossicità acuta Categoria 3
  • Tossicità acuta Categoria 4
  • Tossicità per la riproduzione Categoria 1B
Indicazioni di pericolo
  • H312-Nocivo per contatto con la pelle.
  • H331-Tossico se inalato.
  • H360FD-Può nuocere alla fertilità. Può nuocere al feto.
Consigli di prudenza
  • P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
  • P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
  • P304+P340-IN CASO DI INALAZIONE: trasportare l'infortunato all'aria aperta e mantenerlo a riposo in posizione che favorisca la respirazione.
  • P310-Contattare immediatamente un CENTRO ANTIVELENI/un medico .
  • P405-Conservare sotto chiave.
  • P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
Informazioni supplementari
  • MIXTURE LIST-Contiene: N,N-dimethylacetamide

For Research Use Only. Not for use in diagnostic procedures.

Correzione del contenuto del prodotto

Fornite il vostro feedback sul contenuto del prodotto compilando il modulo sottostante.

Titolo del prodotto

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.

Grazie per averci aiutato a migliorare il nostro sito web. Il vostro feedback è stato inviato