Thermo Scientific™ POROS™ CaptureSelect™ FSH Affinity HPLC Columns

Codice prodotto. 18416428 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
30 mm
50 mm
100 mm
Diametro (sistema metrico):
2.1 mm
4.6 mm
Dimensione della confezione:
Pezzo
3 product options available for selection
Product selection table with 3 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Lunghezza (sistema metrico) Diametro (sistema metrico) Dimensione della confezione
18416428 30 mm 2.1 mm Pezzo
18496558 50 mm 4.6 mm Pezzo
18466648 100 mm 4.6 mm Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 3 options available.
3 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 18416428 Fornitore Thermo Scientific™ N. del fornitore 4481822
  • ONLINE EXCLUSIVE PRICE
    2910.00€
    2760.00€ / pezzi 1
    Risparmia 150.00€
    5% Sconto
 Articolo soggetto a restrizioni
In stock
Aggiungi al carrello
Aggiungi al carrello

missing translation for 'validMainframeMsg'

Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates.

Analytical teams that support biologic drug development require rapid, sensitive, and precise methods for protein quantitation from cell culture, fermentations broths, or purification intermediates. It is critical for biopharmaceutical manufacturers to be able to monitor bioreactor product titers to determine when to harvest or abort a reactor cycle. POROS CaptureSelect FSH HPLC columns incorporate the advantages of high-speed POROS chromatography resins with the unique selectivity of CaptureSelect ligands, enabling 3-minute quantitation of human follicle stimulating hormone (FSH).

Features of this class of chromotography columns:

  • Broad utility—POROS A, G, and CaptureSelect affinity ligands address most biological drug classes
  • Rapid—POROS resins offer fast quantitation or purification of immunoglobulins and fusion proteins
  • Hands-off operation—HPLC method can be automated for streamlined operation
  • Robust—delivers high-performance purification over hundreds of chromatography cycles

High Speed with High Specificity

The combination of CaptureSelect FSH affinity ligand with POROS 20 μm resin provides a high flow-rate, high performance chromatography solution for the rapid quantitation and small-scale purification of FSH.

POROS high performance chromatography allows for the quantitation of product from clarified harvest or partially purified intermediates—typically in less than 3 minutes. Moreover, only minimal sample preparation (0.2 μm filtration) is required, and the eluted product is highly purified and suitable for further analysis, including mass spectrometry.

Automation

POROS affinity chromatography columns are suitable for use with HPLC systems, allowing for the automation of chromatography, data collection, and data analysis. In addition, the immobilized affinity ligands enable one method and buffer system to be used across a class of molecules, streamlining analytical approaches.

Multiple Cycles

Proper sample preparation, adherence to column operating instructions, and the use of an optimized column cleaning regime results in strong re-use performance. POROS affinity chromatography columns can be cycled hundreds of times for cost-effective and reproducible quantitation or purification.

TRUSTED_SUSTAINABILITY

Specifica

Diametro (sistema metrico) 2.1 mm
Include Column includes EZ grip fittings and column test certificate.
Lunghezza (sistema metrico) 30 mm
Pressione max 180 bar
Dimensione particelle 20 μm
Dimensione del poro 2000 Å
Quantità 1 Column
Fase stazionaria Follicle Stimulating Hormone affinity ligand, humanspecific
Product Line CaptureSelect, POROS
Capacità di legame 1.5 mg/mL resin
Elution Volume Max <100 μL
Compatibilità ad alta produttività Automated Protocols
Tipo di campione Biopharmaceutical Purification Sample, Bulk Drug Substance Sample, Cell Cultures
Target Molecule Follicle Stimulating Hormone
Volume (sistema metrico) 0.1 mL
Tipo di colonna Affinity
Fase Affinity Separation
Materiale PEEK
Purification Target Follicle Stimulating Hormone
Tecnica Antibody Affinity Chromatography
Da utilizzare con (applicazione) FPLC
Product Type Column
Vedi altri risultati Mostra meno risultati

For Research Use Only. Not for use in diagnostic procedures.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.