Learn More
Descrizione
- Sera-Xtracta Virus/Pathogen Kit for high-throughput total nucleic acid (DNA/RNA) isolation from bacteria and viruses including Adenovirus (Type 14), Influenza A (H3N2) and COVID-19.
- Offers the advantages of solid phase extraction (using magnetic beads) and reproducible yields.
- Simplified protocol can be adapted for both manual and automated high-throughput processing.
- Scalable up to 400 μL of sample.
- Rapid extraction procedure can be completed in less than 30 minutes.
- For use with respiratory biological matrices, blood and universal transport media to support the sensitive downstream detection of viruses and other pathogens found in low concentrations.
- Compatible with molecular biology techniques, including quantitative polymerase chain reaction (qPCR, RT-qPCR), droplet digital PCR (ddPCR), and next-generation sequencing (NGS).
- Sera-Xtracta Virus/Pathogen Kit provides a simple and rapid method to optimize the workflow for sensitive detection system for viruses and other pathogens found in low concentrations.
- Optimize isolation workflows to reduce bottlenecks
- To address this bottleneck, our robust extraction chemistry ensures that the total nucleic acid is selectively bound to the superparamagnetic beads, while impurities are efficiently removed during the quick wash steps.
- The resulting high quality total nucleic acid is then eluted from the bead using a suitable elution buffer of choice.
- The rapid Sera-Xtracta workflow gives pure, high-quality nucleic acid suitable for sensitive molecular testing.
Infectious diseases affect millions of people every year. Particularly virulent and multi-drug resistant agents are increasingly responsible for infections with ever-expanding complexities. The design, manufacture and validation of assays for these pathogenic agents requires the successful purification of high-quality nucleic acid. This is essential to any molecular research and testing workflow. The nucleic acid purification process can be a bottleneck because sufficient nucleic acid from biological samples is required to meet a sensitivity threshold for assays which are designed to help identify, map or make informed decisions on latent and active infections.
Specifica
Specifica
| Content And Storage | All reagents can be stored at ambient temperature (15°C–25°C). For Proteinase K, once reconstituted, store at 2°C–8°C |
| Include | Binding/Lysis Reagent 60 mL; Wash Buffer 100 mL; SeraSil-Mag 400 beads 1.1 mL; SeraSil-Mag 700 beads 1.1 mL; Proteinase K 30 mg (lyophilized) |
| Quantità | 96 Purifications |
| Dimensione campione | Up to 400 μL of sample |
| Durata del test | Can be completed in less than 30 minutes |
Sicurezza e movimentazione
- Sera-Xtracta Virus/Pathogen Kit (96 extractions)
- Pericolo
- Tossicità acuta Categoria 4
- PERICOLO A LUNGO TERMINE PER L'AMBIENTE ACQUATICO Cronico 3
- Lesione oculare grave/irritazione oculare Categoria 2
- Sensibilizzante delle vie respiratorie Categoria 1
- Corrosione/irritazione della pelle Categoria 2
- Tossicità specifica per organi bersaglio (esposizione singola) Categoria 3
- H302-Nocivo se ingerito.
- H315-Provoca irritazione cutanea.
- H319-Provoca grave irritazione oculare.
- H334-Può provocare sintomi allergici o asmatici o difficoltà respiratorie se inalato.
- H335-Può irritare le vie respiratorie.
- H412-Nocivo per gli organismi acquatici con effetti di lunga durata.
- P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P264-Lavare accuratamente dopo l'uso.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P304+P340-IN CASO DI INALAZIONE: trasportare l'infortunato all'aria aperta e mantenerlo a riposo in posizione che favorisca la respirazione.
- P405-Conservare sotto chiave.
- P501b-Smaltire il prodotto/recipiente in conformità con le disposizioni locali/regionali/nazionali/internazionali.
- MIXTURE LIST-Contiene: thiocyanic acid, hydrochloric acid, proteases
- UNKNOWN ACUTE-La miscela contiene 20% di componenti la cui tossicità acuta non è nota.
Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.