missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TRACE™ GC Columns for Dioxin and PCB Analysis

Codice prodotto. 10299314 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
30 m
50 m
60 m
Spessore pellicola:
0.1 μm
0.25 μm
Stationary Phase:
Trace™ TR-Dioxin 5 MS
Trace™ TR-PCB 8 MS
Dimensione della confezione:
Pezzo
4 product options available for selection
Product selection table with 4 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Lunghezza (sistema metrico) Spessore pellicola Stationary Phase unitSize
10299314 30 m 0.1 μm Trace™ TR-Dioxin 5 MS Pezzo
10478464 60 m 0.1 μm Trace™ TR-Dioxin 5 MS Pezzo
10351335 60 m 0.25 μm Trace™ TR-Dioxin 5 MS Pezzo
10085834 50 m 0.25 μm Trace™ TR-PCB 8 MS Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 4 options available.
4 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 10299314 Fornitore Thermo Scientific™ N. del fornitore 26AF047P
Aggiungi al carrello
Aggiungi al carrello
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Analyze dioxins and PCBs with high-resolution GC/MS for unsurpassed performance and reproducibility.

Analyze dioxins and polychlorinated biphenyls (PCBs) with custom-tailored Thermo Scientific™ TRACE™ GC Columns for Dioxin and PCB Analysis for unsurpassed performance and reproducibility. Optimized to meet the requirements of high-resolution GC/MS methods, these columns deliver optimum performance with exceptional stability and very low bleed. These low-polarity columns provide wide coverage of the 17 cogeners with the highest toxicological significance (2,3,7,8-chlorine substituted congeners).

Columns Tailored Specifically for Dioxins and PCBs:
  • TRACE TR-Dioxin 5MS: dioxin and furan testing
  • TRACE TR-PCB 8MS: high-resolution GC/MS analysis of PCBs
  • Excellent Quality and Reproducibility
  • Low bleed, even at elevated temperatures
  • Outstanding robustness for difficult separations
  • Reliable and reproducible performance
TRUSTED_SUSTAINABILITY

Specifica

Da utilizzare con (applicazione) Furan (PCDF) Analysis, GC/MS for Furan (PCDF) Analysis, GC/MS for PCB Congener Analysis
Spessore pellicola 0.1 μm
Lunghezza (sistema metrico) 30 m
Descrizione 30 m x 0.25 mm x 0.1 μm
Diametro (sistema metrico) 0.25 mm
Tipo USP G27, G36
Stationary Phase Trace™ TR-Dioxin 5 MS
Diametro (sistema metrico) interno 0.25 mm
Product Line TRACE
Temperatura max (sistema metrico) 360/370°C

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.