missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TraceGOLD TG-1MT Metal GC Columns

Codice prodotto. 15820920 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
10 m
12 m
15 m
30 m
5 m
6 m
Diametro (sistema metrico) interno:
0.25 mm
0.53 mm
Spessore pellicola:
0.1 μm
0.15 μm
0.25 μm
0.5 μm
0.88 μm
1 μm
2.65 μm
Dimensione della confezione:
Pezzo
9 product options available for selection
Product selection table with 9 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Lunghezza (sistema metrico) Diametro (sistema metrico) interno Spessore pellicola unitSize
15820920 10 m 0.53 mm 2.65 μm Pezzo
12602745 5 m 0.53 mm 0.88 μm Pezzo
15257488 12 m 0.53 mm 1 μm Pezzo
12612745 5 m 0.53 mm 0.1 μm Pezzo
11805712 30 m 0.25 mm 1 μm Pezzo
11835712 6 m 0.53 mm 0.15 μm Pezzo
11895702 30 m 0.25 mm 0.5 μm Pezzo
11885702 30 m 0.25 mm 0.25 μm Pezzo
11875702 15 m 0.25 mm 0.25 μm Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 9 options available.
9 options
This item is not returnable. View return policy
Product Code. 15820920 Supplier Thermo Scientific™ Supplier No. 26M993480
Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

Push the limits of your analyses with these nonpolar, metal columns designed for elevated temperature use.

Push the limits of your analyses with Thermo Scientific™ TraceGOLD™ TG-1MT GC Columns. These nonpolar, metal columns allow you to work a temperatures up to 430°C with no compromise in performance when analyzing highly active and aggressive compounds.

Engineered for Superior Performance:
  • Nonpolar, 100% dimethyl polysiloxane
  • Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
  • Stable to 430°C
  • Applications:
  • Hydrocarbons
  • Solvent impurities
  • Polychlorinated biphenyl (PCB) congeners
  • Aroclor mixes
  • Simulated distillation
  • Drugs of abuse
  • Natural gas odorants
  • Essential oils
  • Pesticides
  • A Leap Forward in Performance with Low Bleed and Superior Inertness:
  • A low bleed, stable column produces consistent results.
  • Low baseline noise enables improved limits of detection with enhanced resolution of low level analytes. Minimizing column bleed extends the column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult compounds.
  • Recommended For:
  • Hydrocarbons
  • Gasoline range
  • Chlorinated aromatics
  • Organochlorine pesticides
  • Organophosphorous pesticides
  • Polycyclic aromatic hydrocarbons (PAHs)
  • Paraffins
  • Polywax
  • Pyrethroids
  • Semivolatiles
  • Xylenes
  • Similar To:
  • MXT™-1
  • DB-1
  • DB-1MS
  • HP-1
  • HP-1MS
  • Ultra-1
  • SPB™-1
  • Equity™-1
  • MDN-1
  • CP-Sil 5 CB
  • VF-1ms
  • ZB-1HT
  • TRUSTED_SUSTAINABILITY

    Specifications

    Temperatura max Up to 430°C
    Diametro (sistema metrico) 0.53 mm
    Diametro (sistema metrico) interno 0.53 mm
    Product Line TraceGOLD
    Stationary Phase TraceGOLD™ TG-1MT
    Tipo USP G2
    Da utilizzare con (applicazione) Hydrocarbons Anaylsis, GC/MS for Hydrocarbons, GC/MS for Gasoline Range Organics (GROs), GC/MS for Drugs of Abuse, GC/MS for PCBs
    Spessore pellicola 2.65 μm
    Lunghezza (sistema metrico) 10 m
    Polarità Non-Polar

    Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

    Product Title
    Select an issue

    By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.