missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TraceGOLD™ TG-WaxMT Metal GC Columns

Codice prodotto. 11870463 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
15 m
30 m
60 m
Diametro (sistema metrico):
0.25 mm
0.53 mm
Dimensione particelle:
0.10 μm
0.25 μm
0.5 μm
1 μm
1.5 μm
Dimensione della confezione:
Pezzo
Codice prodotto. Lunghezza (sistema metrico) Diametro (sistema metrico) Dimensione particelle unitSize
11870463 60 m 0.25 mm 0.25 μm Pezzo
11810473 15 m 0.53 mm 1 μm Pezzo
11890463 30 m 0.25 mm 0.5 μm Pezzo
11840463 15 m 0.25 mm 0.25 μm Pezzo
11830463 15 m 0.25 mm 0.10 μm Pezzo
11800473 30 m 0.53 mm 0.5 μm Pezzo
11850463 30 m 0.25 mm 0.25 μm Pezzo
11820473 30 m 0.53 mm 1 μm Pezzo
11860463 30 m 0.53 mm 0.25 μm Pezzo
11830473 30 m 0.53 mm 1.5 μm Pezzo
10 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Codice prodotto. 11870463

Marca: Thermo Scientific™ 26M881540

Solo null disponibili
Aggiungi al carrello
Aggiungi al carrello
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Ensure excellent column-to-column reproducibility using the Thermo Scientific™ TraceGOLD™ TG-WaxMT GC Columns.

Engineered for Superior Column-to-Column Reproducibility
  • Polar phase, polyethylene glycol
  • Polar-deactivated surface tightly binds polymer for excellent thermal stability
  • Resists oxidative damage, damage from strongly acidic or basic volatiles better than silicone solid phases
  • Equivalent to USP G14, G15, G20 and G39 phases
Applications:
  • Fatty acid methyl esters (FAMEs)
  • Flavor compounds
  • Essential oils
  • Amines
  • Solvents
  • Xylene isomers
  • EPA Method 603 for Acrolein/Acrylonitrile

A Leap Forward in Column Performance with Low Bleed and Superior Inertness
  • This low-bleed, stable column produces consistent results.
  • Low baseline noise enables improved limits of detection with enhanced resolution of low level analytes.
  • Minimizing column bleed extends column lifetime, leading to higher productivity.
  • Reducing column bleed increases reproducibility of the stationary phase over time, resulting in greater run-to-run and batch-to-batch reproducibility.
  • Superior inertness ensures excellent peak shape and sensitivity, especially for highly active or difficult-to-analyze compounds.

Recommended Use:
  • Aldehydes
  • Essential oils
  • Solvents
  • Xylenes
  • Alternative Use:
  • Acids
  • Alcohols
  • Alcohols in beverages
  • Alditol acetates (sugars)
  • Amines–Aliphatic
  • Amines–Aromatic

Similar To:
  • MXT™-Wax
  • DB-WAX
  • DB-WAXetr
  • HP-Wax
  • HP-Innowax
  • SUPELCOWAX™ 10
  • CP-Wax 52 CB
TRUSTED_SUSTAINABILITY

Specifica

Temperatura max 260°C
Diametro (sistema metrico) 0.25 mm
Diametro (sistema metrico) interno 0.25 mm
Product Line TraceGOLD
Stationary Phase TraceGOLD™ TG-WAXMS
Tipo USP G14, G15, G16, G20, G39
Da utilizzare con (applicazione) GC for EPA Method 603 for Acrolein/Acrylonitrile, GC for Fatty Acid Methyl Esters (FAMEs), Flavor Compounds, Essential Oils, Amines, Solvents, and Xylene Isomers
Dimensione particelle 0.25 μm
Gamma di temperatura 40°C°C to 260°C
Spessore pellicola 0.25 μm
Lunghezza (sistema metrico) 60 m
Polarità Polar
Vedi altri risultati Mostra meno risultati
Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.