Thermo Scientific™ Acclaim™ Surfactant HPLC Columns

Codice prodotto. 11311943 Sfoglia Tutto Thermo Scientific Prodotti
Cambia vista
Click to view available options
Lunghezza (sistema metrico):
10 mm
150 mm
250 mm
Diametro (sistema metrico):
2.1 mm
3 mm
4.6 mm
Dimensione particelle:
3 μm
5 μm
Dimensione della confezione:
Pezzo
pezzi 2
8 product options available for selection
Product selection table with 8 available options. Use arrow keys to navigate and Enter or Space to select.
Codice prodotto. Lunghezza (sistema metrico) Diametro (sistema metrico) Dimensione particelle unitSize
11311943 150 mm 2.1 mm 3 μm Pezzo
11311823 150 mm 4.6 mm 5 μm Pezzo
11321823 250 mm 4.6 mm 5 μm Pezzo
11331903 150 mm 2.1 mm 5 μm Pezzo
11361923 10 mm 4.6 mm 5 μm pezzi 2
11381913 10 mm 2.1 mm 5 μm pezzi 2
11321983 10 mm 3 mm 5 μm pezzi 2
11301943 150 mm 3 mm 3 μm Pezzo
Use arrow keys to navigate between rows. Press Enter or Space to select a product option. 8 options available.
8 options
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso
Codice prodotto. 11311943 Fornitore Thermo Scientific™ N. del fornitore 070085
Solo null disponibili
Aggiungi al carrello
Aggiungi al carrello
Les retours ne sont pas autorisés pour ce produit. Consulta la politica di reso

Use for outstanding separation of anionic, nonionic, and cationic surfactants with ELSD and RI detectors.

Achieve outstanding separation of all classes of surfactants with Thermo Scientific™ Acclaim™ Surfactant LC Columns. These high-efficiency, silica-based columns provide excellent resolution and throughput for HPLC separations using UV-Vis, evaporative light scattering (ELSD) or refractive index (RI) detection. The novel surface chemistry creates a unique polarity that offers significantly improved resolution for individual oligomers of ethoxylated surfactants compared with conventional C18 columns.

When you want to use a charged aerosol detector (CAD) or a mass spectrometer (MS) for your surfactant analysis, select the Acclaim Surfactant Plus LC column. This high-resolution, high-efficiency, high-throughput column has similar selectivity to the Acclaim Surfactant column but has exceptionally low bleed for optimal performance with higher sensitivity detectors.

Unmatched Performance for Separating a Broad Range of Surfactants

  • Ideal selectivity for separation of anionic, nonionic, cationic and amphoteric surfactants
  • Resistant to dewetting under highly aqueous mobile phase conditions
  • Retains highly hydrophilic compounds, such as hydrotropes
  • Excellent peak shapes, especially for cationic surfactants
  • Rugged separations under a variety of conditions
  • Available in 3.0 and 5.0μm particle sizes and 2.1, 3.0 and 4.6mm diameters, with 150 and 250mm lengths

About the Family of Acclaim Specialty HPLC Columns
Acclaim Specialty Columns have been developed, manufactured and tested to meet the separation needs of specific applications. These columns are based on novel and unique chemistries and provide superior resolution with ease-of-use.

  • Use-tested to guarantee consistent separations
  • Ideal selectivity for separating specific target analytes
  • Excellent peak shapes
  • Performance tested to ensure high quality and reliability for specific chromatographic separations
TRUSTED_SUSTAINABILITY

Specifica

Formato colonna Colonna analitica
Diametro (sistema metrico) 2.1 mm
Da utilizzare con ELSD, SCD, UV-Vis Detector
Lunghezza (sistema metrico) 150 mm
Pressione max 5500 psi (380 bar)
Impurità del metallo <10.0 ppm Total Metal, <3.0 ppm Individual Metal
Forma particelle Spherical
Dimensione particelle 3 μm
Distribuzione dimensionale delle particelle <1.3
pH 2.5 to 7.5
Dimensione del poro 120 Å
Volume dei pori 0.9 to 1 mL/g
Quantità Each
Surface Area 300 m²/g
Temperatura 60 °C
Fase stazionaria Proprietary
Product Line Acclaim
Materiale di impaccamento diossido di silicio ultrapuro completamente poroso, sferico
Carico di carbonio 12%
Tipo di colonna Specialty/Application Specific
Con tappo
Tipo Analytical Column
Green Features FSC
Vedi altri risultati Mostra meno risultati

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Titolo del prodotto
Selezionare un problema

Facendo clic su Invia, l'utente riconosce che potrebbe essere contattato da Fisher Scientific in merito al feedback fornito in questo modulo. Non condivideremo le vostre informazioni per altri scopi. Tutte le informazioni di contatto fornite saranno conservate in conformità con la nostra Politica sulla privacy. Informativa sulla privacy.