Learn More
Lovibond™ MD 100 3-in-1 Photometer: Chlorine LR, Chlorine HR, Chlorine Dioxide
Descrizione
Includes
Instrument in a carrying case, three round glass vials with lids, one stirring rod and brush, Chlorine E HR (KI) tablets (100 pack), Acidifying GP tablets (100 pack), DPD No. 1 tablets (100 pack), DPD No. 3 tablets (100 pack), Hardcheck P tablets (100 pack), 4 x AAA batteries, warranty information, Certificate of compliance, instruction manual
The calibration and software-based adjustment options mean that the MD 100 is also suitable for use as a testing instrument. The tests are conducted using either Lovibond tablet reagents with long term stability and a guaranteed minimum five or 10 year shelf life, VARIO powder reagents or using liquid reagents.
- Waterproof (as defined in IP68, 1 hour at 0.1m)
- Automatic switch-off
- Real-time clock and date calibration mode
- Backlit LCD display (on keypress)
- Factory calibration and user calibration; Reset to factory calibration possible
- Internal ring memory for 16 data sets
- Infrared interface for test data transfer
Reagents Tablets
Each tablet is hermetically sealed within an individual aluminum foil pocket, protecting against challenging environmental conditions. This packaging keeps each tablet in perfect condition, right up until the time it is needed by the user.
Specifications
- Chlorine LR Range: 0.01 to 6.0mg/L Cl2
- Chlorine HR Range: 5 to 200mg/L Cl2
- Chlorine Dioxide Range: 0.02 to 11mg/L ClO2
- Light source: LED, interference filter (IF) and photosensor in transparent cell chamber
- Wavelength Accuracy: ±1nm
- Photometric Accuracy: 3% FS (T = 20°C to 25°C)
- Photometric Resolution: 0.01 A
- Temperature: 5° to 40°C
- Relative Humidity: 30 to 90% (non condensing)
- Power Supply: 4 AAA batteries
- Operating Time: approx. 17 hours or 5000 test measurements in continuous mode when display backlight is off
- Dimensions (L x W x H): 15.5 x 7.5 x 3.5cm
- Weight: basic unit approx. 260g
Note
Specifications for each type of tablet as well as a Certificate of Analysis for each lot is available in the download area at www.lovibond.com.
Specifica
Specifica
| Tipo | MD 100 3-in-1 Photometer: Chlorine LR, Chlorine HR, Chlorine Dioxide |
| Tipo di display | Backlit LCD |
| Accuracy | 3% FS |
| Altezza (sistema metrico) | 3.5 cm |
| Include | Instrument in a carrying case, three round glass vials with lids, one stirring rod and brush, Chlorine E HR (KI) tablets (100 pack), Acidifying GP tablets (100 pack), DPD No. 1 tablets (100 pack), DPD No. 3 tablets (100 pack), Hardcheck P tablets (100 pack), 4 x AAA batteries, warranty information, Certificate of compliance, instruction manual |
| Lunghezza (sistema metrico) | 15.5 cm |
| Memoria | Internal ring memory for 16 data sets |
| Sorgente luminosa | LED |
| Range | 0.01 to 6.0mg Cl2, 5 to 200mg/L Cl2, 0.02 to 11mg/L ClO2 |
| Risoluzione | 0.01 A |
| Vedi altri risultati |
Sicurezza e movimentazione
- MD100 CHLORINE LR/HR-CHLORINE DIOXIDE TABLETS - PH .
- Pericolo
- Lesione oculare grave/irritazione oculare Categoria 2
- Sostanze e miscele corrosive per i metalli Categoria 1
- Corrosione/irritazione della pelle Categoria 2
- Tossicità specifica per organi bersaglio (esposizione ripetuta) Categoria 1
- Tossicità specifica per organi bersaglio (esposizione ripetuta) Categoria 2
- Tossicità specifica per organi bersaglio (esposizione singola) Categoria 3
- H290-Può essere corrosivo per i metalli.
- H315-Provoca irritazione cutanea.
- H319-Provoca grave irritazione oculare.
- H335-Può irritare le vie respiratorie.
- H372-Provoca danni agli organi.
- H373-Può provocare danni agli organi.
- P234-Conservare soltanto nel contenitore originale.
- P260-Non respirare la polvere/i fumi/i gas/la nebbia/i vapori/gli aerosol.
- P264-Lavare accuratamente dopo l'uso.
- P280-Indossare guanti/indumenti protettivi/Proteggere gli occhi/il viso.
- P302+P352-IN CASO DI CONTATTO CON LA PELLE: lavare abbondantemente con acqua/.
- P305+P351+P338-IN CASO DI CONTATTO CON GLI OCCHI: sciacquare accuratamente per parecchi minuti. Togliere le eventuali lenti a contatto se è agevole farlo. Continuare a sciacquare.
- P312-Contattare un CENTRO ANTIVELENI/un medico/in caso di malessere.
- P314-In caso di malessere, consultare un medico.
- P337+P313-Se l'irritazione degli occhi persiste, consultare un medico.
- MIXTURE LIST-Contiene: potassium iodide, sulphuric acid, citricacid, adipic acid