missing translation for 'onlineSavingsMsg'
Learn More

Thermo Scientific™ TRACE™ TR-BioDiesel GC Columns

Codice prodotto. 10301255 Sfoglia Tutto Thermo Scientific Prodotti
missing translation for 'orderingAttributeHoverText'
Lunghezza (sistema metrico):
10 m
30 m
Diametro (sistema metrico) interno:
0.25 mm
0.32 mm
Spessore pellicola:
0.1 μm
0.25 μm
3 μm
missing translation for 'unitSize'
Pezzo
This item is not returnable. View return policy

Product Code. 10301255

missing translation for 'mfr': Thermo Scientific™ 26AF024P

Only null left
Add to basket
Add to basket
This item is not returnable. View return policy

Determine methanol, fatty acid methyl esters (FAMEs) and glycerides in biodiesel analysis with high performance and reproducibility.

Determine methanol, fatty acid methyl esters (FAMEs) and glycerides in biodiesel analysis with high performance and reproducibility using Thermo Scientific™ TRACE™ TR-BioDiesel GC Columns. Biodiesel is an important component in the development of carbon neutral fuels and specific GC columns within the TRACE range deliver robust performance to meet and exceed the methodology demands for this application area.

Columns Specifically Designed to Meet Your Biodiesel Analysis Needs:
  • TRACE TR-BioDiesel (M); for determination of residual methanol content in biodiesel according to EN Method 14110
  • TRACE TR-BioDiesel (G); for the analysis of total glyceride content according to EN Method 14105
  • TRACE TR-BioDiesel (F); for the analysis of FAME content in biodiesel according to EN Method 14103
  • TRACE TR-BioDiesel (G) ASTM; for the analysis of total glyceride content according to ASTM method D-6584
Excellent Quality and Reproducibility:
  • Low bleed, even at elevated temperatures
  • Outstanding robustness for difficult separations
  • Reliable and reproducible performance
TRUSTED_SUSTAINABILITY

Specifications

Temperatura max 300/320°C
Diametro (sistema metrico) 0.32 mm
Diametro (sistema metrico) interno 0.32 mm
Product Line TRACE
Stationary Phase Trace™ TR-BioDiesel
Tipo USP G1, G2, G38
Da utilizzare con (applicazione) Biodiesel Analysis
Spessore pellicola 0.1 μm
Lunghezza (sistema metrico) 10 m
Descrizione Bacillus Pumilus; ATCC 14884
Product Content Correction

Your input is important to us. Please complete this form to provide feedback related to the content on this product.

Product Title

By clicking Submit, you acknowledge that you may be contacted by Fisher Scientific in regards to the feedback you have provided in this form. We will not share your information for any other purposes. All contact information provided shall also be maintained in accordance with our Privacy Policy.

Thank You! Your feedback has been submitted. Fisher Scientific is always working to improve our content for you. We appreciate your feedback.