Thermo Scientific™ Orion Lab Star PH111 Bench pH Meters
Orion Lab Star PH111 benchtop pH meters measure pH or ORP with mV and temperature, feature a large backlit display for easy viewability, and offer small footprint to save bench space. The Orion Lab Star pH meter is ideal for simplified, budget-friendly lab testing and data recording.
Tipo di display | LCD, 5 in. Backlit |
---|---|
Intervallo (mV) | ±2000.0 |
Precisione (mV) | ±0.2 or ±0.05%, whichever is greater |
Calibrazione della sonda di temperatura | 1 point temperature offset calibration |
Measurement Modes | pH with mV and Temperature,ORP with mV and Temperature |
Certificazione/Conformità | CE, TUV 3-1, FCC Class A |
Risoluzione (mV) | 0.1 mV |
Intervallo di temperatura (sistema imperiale) | 23.0°F to 221.0°F |
Adattatore CA | Universal 100-240 V 50/60 Hz power supply with twist-and-lock meter connection and interchangeable wall plugs for US/Japan, Euro, UK/Singapore, Australia/New Zealand and China outlets |
Punti dati | 500 with Date and Time Stamp |
Uscita allarme | Calibration reminder alarm |
Uscite | Computer or printer (STARA-106) |
Selezione della temperatura | Manual or automatic with ATC temperature probe |
Warranty | 3 year meter warranty |
Punti di calibrazione (pH) | 1 to 5 points |
Precisione (Temperatura) | ±0.3°C/±0.5°F |
Peso (sistema imperiale) | 1.54 lb. |
Ingressi | BNC for pH or ORP, 8-pin MiniDIN for ATC |
Protezione IP | IP54 |
Tipo di funzione registro | Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode |
Calibration Points | 1 (ORP) |
Dettagli di gestione dei dati | Transfer single or all data points to printer or computer |
Risoluzione (temperatura) | 0.1°C, 0.1°F |
Backlight Option | Yes |
Peso (sistema metrico) | 700 grams |
Calibrazione | pH, ORP and temperature |
Temperature Range (Metric) | -5.0°C to +105.0°C |
Intervallo (ORP) | ±2000.0 mV with ±250 mV offset |
Risoluzione (pH) | 0.001, 0.01, 0.1 |
Memoria | Non-volatile |
Thermo Scientific™ pHmetro da banco Orion Star™ A211
SureTRACE
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Misurazione affidabile di pH, mV, ORP e temperatura con il pHmetro da banco Thermo Scientific™ Orion™ Star A211 per analisi di laboratorio avanzate e interfaccia stampante o computer
Tipo di display | LCD (grafico con retroilluminazione) |
---|---|
Precisione (mV) | ±0.2 mV o ±0.05% della lettura a seconda di quale sia il valore maggiore |
Calibrazione della sonda di temperatura | Calibrazione offset della temperatura a 1 punto |
Measurement Modes | pH, mV, mV relativi (RmV) o ORP con temperatura,mV,Relative mV,ORP with Temperature |
Punto isopotenziale | pH 7.000 |
Intervallo umidità relativa | Da 5 a 85%, senza condensa |
Lingue | Inglese, spagnolo, francese, italiano, tedesco e cinese; portoghese e coreano sono disponibili con l'aggiornamento del software |
Certificazione/Conformità | CE, TUV 3-1, FCC classe A |
Risoluzione (mV) | 0.1 mV |
Intervallo di temperatura (sistema imperiale) | Da 22.0° a 221.0 °F |
Metodi | 10 per canale con protezione mediante password |
Adattatore CA | Adattatore di alimentazione universale 50-60 Hz, 100-240 V CA (n. cat. 1010003) |
Modello | Misuratore da banco di pH/mV/RmV/ORP/temperatura Orion Star A211 |
Autonomia della batteria | 800 ore |
Punti dati | 2000 con indicazione di data e ora |
Uscita allarme | Allarme di limite alto/basso, allarme di richiesta calibrazione |
Stabilità | Impostazioni rapida, media, lenta o stabilità Smart; possibilità di disattivazione o impostazione automatica del calcolo della media Smart |
Uscite | USB, RS-232 |
Selezione della temperatura | Manuale o automatica con sonda di temperatura ATC |
Intervallo (mV relativo) | ±2000.0 mV |
Precisione (Temperatura) | ±0.1 °C |
Temperatura (sistema imperiale) operativa | Da 41 a 113 °F (temperatura ambiente) |
Peso (sistema imperiale) | 2 libbre |
Ingressi | BNC (elettrodo pH o ORP), spinotto singolo (elettrodo di riferimento), MiniDIN a 8 pin (sonda di temperatura ATC), input agitatore (sonda agitatore) |
Tipo di batteria | 4 AA (vendute separatamente) |
Protezione IP | IP-54 |
Tipo di funzione registro | Registrazione automatica dei dati con le modalità di misurazione a lettura automatica e temporizzata |
Tastierino | Completo di tasti funzione specifici dei menu e tasti a doppia funzione scorrimento/scelta rapida |
Calibration Points | 43470 |
Canali | 1 |
Intervallo (pH) | Da -2.000 a 20.000 |
Dettagli di gestione dei dati | Invia dati singoli, intervalli di dati o tutti i dati alla stampante o al computer |
Precisione (pH) | ±0.002 pH |
Temperatura (sistema metrico) operativa | Da 5° a 45 °C (temperatura ambiente) |
Risoluzione (temperatura) | 0.1 °C, 0.1 °F |
Alimentazione | Adattatore CA universale (incluso) o 4 batterie AA (vendute separatamente) |
Backlight Option | Sì, selezionabile |
Peso (sistema metrico) | 0.9 kg |
Calibrazione | pH con opzioni di impostazione di calibrazione, mV relativi (RmV), ORP e temperatura |
Temperature Range (Metric) | Da -5.0° a +105.0 °C |
Intervallo (ORP) | ±2000.0 mV |
Risoluzione (pH) | 0.1, 0.01, 0.001 |
Memoria | La memoria non volatile conserva i dati registrati, i registri di calibrazione e le impostazioni dell'apparecchio |
Thermo Scientific™ Orion™ Versa Star Pro™ pH/LogR™ Benchtop Meter
SureTRACE
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Get premium performance and ultimate flexibility with our benchtop meter with pH/LogR module for pH, mV, ORP and LogR temperature technology.
Power Rating | DC input: 9VDC, 1A |
---|---|
Tipo di display | LCD, Color Graphic with User-Customizable Options |
Precisione (mV) | ±0.2 or ±0.05%, whichever is greater |
Calibrazione della sonda di temperatura | 1 point temperature offset calibration, 3 point LogR temperature calibration |
Measurement Modes | pH with LogR Temperature,mV,Relative mV,ORP with Temperature |
Punto isopotenziale | 7.000pH (adjustable) |
Intervallo umidità relativa | 5 to 85%, non-condensing |
Lingue | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Certificazione/Conformità | CE, TUV 3-1, FCC Class A |
Risoluzione (mV) | 0.1mV |
Intervallo di temperatura (sistema imperiale) | 22.0°F to 221.0°F |
Metodi | 10 per channel |
Adattatore CA | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Punti dati | 2000 with Date and Time Stamp |
Uscita allarme | Set point alarm, high/low limit alarm, calibration due alarm |
Stabilità | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Uscite | USB, RS-232 |
Selezione della temperatura | Manual or automatic with ATC temperature probe, automatic with pH electrode using LogR mode |
Intervallo (mV relativo) | ±2000.0mV |
Precisione (Temperatura) | ±0.1°C |
Temperatura (sistema imperiale) operativa | 41°F to 113°F (ambient) |
Peso (sistema imperiale) | 2.5 lb., modules add 0.5 lb. each |
Ingressi | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
Protezione IP | IP-54 |
Tipo di funzione registro | Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual |
Tastierino | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Canali | 4 - customizable with modules |
Intervallo (pH) | -2 to 20 |
Dettagli di gestione dei dati | Transfer single, range or all data points to printer or computer |
Precisione (pH) | ±0.002 |
Temperatura (sistema metrico) operativa | 5°C to 45°C (ambient) |
Risoluzione (temperatura) | 0.1°C, 0.1°F |
Alimentazione | Universal AC adapter (included) |
Backlight Option | Yes |
Peso (sistema metrico) | 1.2 kg, modules add 0.2 kg each |
Calibrazione | pH with calibration editing option, relative mV, ORP, LogR temperature and temperature |
Temperature Range (Metric) | -5°C to +105°C |
Intervallo (ORP) | ±2000.0mV |
Risoluzione (pH) | 0.001, 0.01, 0.1 |
Memoria | Non-volatile memory preserves data log, calibration log and meter settings |
Thermo Scientific™ Orion™ Versa Star Pro™ Benchtop pH Meter
SureTRACE
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Supporta la tracciabilità con accesso garantito ai certificati e notifiche tempestive in caso di cambiamenti.
Per saperne di più
Get premium performance and ultimate flexibility with our benchtop pH meter for pH, mV, ORP and temperature measurements on customizable color display.
Power Rating | DC input: 9VDC, 1A |
---|---|
Tipo di display | LCD, Color Graphic with User-Customizable Options |
Precisione (mV) | ±0.2 or ±0.05%, whichever is greater |
Calibrazione della sonda di temperatura | 1 point temperature offset calibration |
Measurement Modes | pH,mV,Relative mV,ORP with Temperature |
Punto isopotenziale | 7.000pH (adjustable) |
Intervallo umidità relativa | 5 to 85%, non-condensing |
Lingue | English, Spanish, French, Italian, German, Chinese, Portuguese and Korean |
Certificazione/Conformità | CE, TUV 3-1, FCC Class A |
Risoluzione (mV) | 0.1mV |
Intervallo di temperatura (sistema imperiale) | 22.0°F to 221.0°F |
Metodi | 10 per channel |
Adattatore CA | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. STARA-PWR) |
Punti dati | 2000 with Date and Time Stamp |
Uscita allarme | Set point alarm, high/low limit alarm, calibration due alarm |
Stabilità | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting |
Uscite | USB, RS-232 |
Selezione della temperatura | Manual or automatic with ATC temperature probe |
Intervallo (mV relativo) | ±2000.0mV |
Precisione (Temperatura) | ±0.1°C |
Temperatura (sistema imperiale) operativa | 41°F to 113°F (ambient) |
Peso (sistema imperiale) | 2.5 lb., modules add 0.5 lb. each |
Ingressi | BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), two stirrer inputs (stirrer probe) |
Protezione IP | IP-54 |
Tipo di funzione registro | Automatic with Auto-Read, Timed and Single Shot Measure Modes; Manual |
Tastierino | Numeric with menu-specific function keys and dual purpose scroll/shortcut keys |
Calibration Points | 1 to 6 |
Canali | 4 - customizable with modules |
Intervallo (pH) | -2 to 20 |
Dettagli di gestione dei dati | Transfer single, range or all data points to printer or computer |
Precisione (pH) | ±0.002 |
Temperatura (sistema metrico) operativa | 5°C to 45°C (ambient) |
Risoluzione (temperatura) | 0.1°C, 0.1°F |
Alimentazione | Universal AC adapter (included) |
Backlight Option | Yes |
Peso (sistema metrico) | 1.2 kg, modules add 0.2 kg each |
Calibrazione | pH with calibration editing option, relative mV, ORP and temperature |
Temperature Range (Metric) | -5°C to +105°C |
Intervallo (ORP) | ±2000.0mV |
Risoluzione (pH) | 0.001, 0.01, 0.1 |
Memoria | Non-volatile memory preserves data log, calibration log and meter settings |
Thermo Scientific™ pHmetro da banco pH Orion™ Star A111
Misurazioni di pH, mV e temperatura semplificate con il pHmetro da banco Thermo Scientific™ Orion™ Star A111 che agevola i controlli in laboratorio
Tipo di display | LCD |
---|---|
Intervallo (mV) | ±1600.0 |
Precisione (mV) | ±0.2 or ±0.05%, whichever is greater |
Calibrazione della sonda di temperatura | 1 point temperature offset calibration |
Measurement Modes | pH,mV,Relative mV with Temperature |
Punto isopotenziale | 7.00pH |
Intervallo umidità relativa | 5 to 85%, non-condensing |
Lingue | English |
Certificazione/Conformità | CE, TUV 3-1, FCC Class A |
Risoluzione (mV) | 0.1mV |
Intervallo di temperatura (sistema imperiale) | 22.0°F to 221.0°F |
Adattatore CA | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) |
Modello | Orion Star A111 Benchtop pH/mV/RmV/Temperature Meter |
Autonomia della batteria | 2000 hr. |
Punti dati | 50 |
Stabilità | Smart Stability and Smart Averaging |
Uscite | None |
Selezione della temperatura | Manual or automatic with ATC temperature probe |
Intervallo (mV relativo) | ±1999.9mV |
Warranty | 3 Year Meter Warranty |
Precisione (Temperatura) | ±0.1°C |
Dimensioni (L x P x A) | 24 cm x 18 cm x 11 cm (9.5 in. x 7.1 in. x 4.3 in.) |
Temperatura (sistema imperiale) operativa | 41°F to 113°F (ambient) |
Peso (sistema imperiale) | 2 lb. |
Ingressi | BNC (pH or ORP electrode), 8 pin MiniDIN (ATC temperature probe) |
Tipo di batteria | 4 x AA (sold separately) |
Protezione IP | IP-54 |
Tipo di funzione registro | Automatic with Auto-Read Measure Mode, Manual with Continuous Measure Node |
Tastierino | Simple with highlighted measure key, scroll and shortcut keys |
Canali | 1 |
Intervallo (pH) | -2 to 16 |
Dettagli di gestione dei dati | Internal Data Point Memory |
Precisione (pH) | ±0.01 |
Temperatura (sistema metrico) operativa | 5°C to 45°C (ambient) |
Risoluzione (temperatura) | 0.1°C, 0.1°F |
Alimentazione | Universal AC adapter (included) or 4 AA batteries (sold separately) |
Peso (sistema metrico) | 0.9 kg |
Calibrazione | pH, relative mV (RmV) and temperature |
Temperature Range (Metric) | -5°C to +105°C |
Risoluzione (pH) | 0.01, 0.1 |